Weinmann on YouTubeRSS FeedsWeinmann on Facebook

SOMNOsmart

Meurice J.C., Cornette A., Philip-Joet F., Pepin J.L., Escourrou P., Ingrand P., Veale D., ANTADIR "PCC" Working Group
"Evaluation of autoCPAP devices in home treatment of sleep apnea/hypopnea syndrome"
Sleep Medicine, 8, 695-703, 2007 [more information]

Rigau J., Farré R., Montserrat J.M., Wöhle H., Schöller B., Navajas D.
"Respuesta de los aparatos de CPAP automática al aumento de resistencia de la via aérea superior durante el sueño",
Archivos De Bronchoneumologia, Vol 40, Suppl, 02.06.04,
XXXVII Congreso Nacional de la Sociedad Española de Neumología y Cirugía Torácica, 2004

Rigau J., Farré R., Montserrat J.M., Wöhle H., Navajas D.
"Model study on the change of the pressure applied by automatic CPAP devices when subjected to simulated increases in upper airway resistance",
Somnologie, 8, Suppl 1, S. 69, Nr. P(52), 2004

Abdenbi F., Chambille B., Escourrou P.
"Bench testing of auto-Adjusting positive airway pressure devices",
Eur Respir J, 24, 649-658, 2004 [more information]

Randerath W., Galetke W., Rühle K.-H.
"Auto-adjusting CPAP based on impedance versus bilevel pressure in difficult-to-treat sleep apnea syndrome. A prospective randomized crossover study", Med Sci Monit, 9(8), CR 353-358, 2003 [more information]

Ficker J.H., Clarenbach C.F., Neukirchner C., Fuchs F.S., Wiest G.H., Pour Schahin S., Harsch I.A., Hahn E.G.
"Auto-CPAP therapy based on the forced oscillation technique",
Biomed Technik, 48, 68-72, 2003 [more information]

Ficker J.H., Fuchs F.S., Wiest G.H. Hahn E.G.
"AUTO-CPAP" und "AUTO-Titration": Möglichkeiten und Grenzen selbstregu-lierender CPAP-Systeme",
Atemw.-Lungenkrkh., 28, 3, 120-126, 2002

Randerath W., Rühle K.-H.
"Forcierte Oscillationstechnik in Diagnostik und Therapie schlafbezogener Atmungsstörungen",
Atemw. -Lungenkrkh., 28, 3, 113-119, 2002

Meurice J.C., Cornette A., Philip J.F., Pepin J.L., Escourrou P., Veale D. et Groupe PPC de l`ANTADIR
"Evaluation de l´efficacite des autoppc dans le traitement du syndrome d´apnees/hypopnees (sahs) au sours du sommeil",
XVIIè Congrès de la Société Françeaise de Recherche sur le Sommeil, Strasbourg, 14.-16.11.2002

Ficker J.H.
"Neue Methoden in der Schlafmedizin: Atemwegsobstruktion",
DGSM-Kongress 26.-28.09.02, Göttingen, Somnologie, 6, Suppl 1, Nr. 67, 26, 2002

Ficker J.H.
"Forced oscillation technique for the detection of upper airway obstruction in sleep disordered breathing",
DGSM-Kongress 26.-28.09.02, Göttingen, Somnologie, 6, Suppl 1, Nr. 182, 65, 2002

Buyse B., Cauberghs M., Demedts M.
"Comparison of 2 auto-CPAP devices for treatment of obstructive sleep apnoea",
12th ERS-Kongress, Stockholm, 2002

Buyse B., Cauberghs M., Demedts M.
"The behavior of 2 different auto-CPAP devices in central sleep apnoea",
12th ERS-Kongress, Stockholm, 2002

Abdenbi F., Chambille B., Esourrou P.
"Evaluation de machines auto-pilotees sur modele mecanique su systeme respiratoire",
XVIIè Congrès de la Société Française de Recherche sur le Sommeil, Strasbourg, 14.-16.11.2002

Alfandari D., Joudani R.
"Comparaison de l´efficacite de la pps somnosmart (weinmann) autopilotee a la ppc 418p (tyco) autopilotee",
XVIIè Congrès de la Société Françeaise de Recherche sur le Sommeil, Strasbourg 14.-16.11.2002 und Pathologies Respiratoires du Sommeil, Arcachon, 25.-26.10.2002

Tamisier R.
"SAOS et autres troubles respiratoires nocturnes - épidémiologie, diagnostic et traitement",
Inspirer (ANTADIR, Dan Veale), October, 2001

Randerath W., Schraeder O., Galetke W., Feldmeyer F., Rühle K.-H.
"Autoadjusting CPAP Therapy Based on Impedance Efficacy, Compliance and Acceptance",
Am J Crit Care Med, 163, 652-657, 2001 [more information]

Randerath W., David M., Feldmeyer F., Galetke W., Rühle K.-H.
"Automatic CPAP Based on Impedance - Comparison of Constant CPAP with an Individual Pressure Range",
Somnologie, 5, 121-125, 2001

Randerath W., Galetke W., David M., Siebrecht H., Sanner B., Rühle K.-H.
"Prospective Randomized Comparison Of Impedance - Controlled Auto-Continuous Positive Airway Pressure (APAPFOT) with Constant CPAP",
Sleep Medicine, 2, 115-124, 2001 [more information]

Kessler R., Beau-Faller M., Casel S., Chaouat A., Schott R., Weizenblum E.
"Comparaison de deux appareils d`autotitration de la pression positive continue chez des patients avec un syndrome d`apnée du sommeil",
5e Congrès de pneumologie de langue française", Paris, 24-27.01.2001

Abdenbi F., Chambille B., Escourrou P.
"Evaluation Of Upper Airway During Sleep By Simultaneous Measurements Of Resistance And Oscillating Pressure Signal",
15th ESRS-Kongress, 12.-16.09.2000, Istanbul, J Sleep Res, S. 1, Nr. 2, 9, Suppl 1, 2001

Kessler R., Beau-Faller M., Casel S., Iamandi C., Weitzenblum E.
"Forced oscillation applied to CPAP may reduce the therapeutic pressure in obstructive sleep apnea patients",
Eur Respir J, 16, Suppl 31, 509s, 3553, 2000 

Scholle S., Riger B., Zwacka G.
"Automatische nCPAP-Therapie auf Basis der forcierten Oszillationstechnik (APAPFOT) - Erfahrungen im Kindesalter",
Wien Klin Wochenschr, 112/5, Suppl 2, S11-S12, 2000

Randerath W., Galetke W., David M., Rühle K.-H.
"Efficiacy, acceptance and compliance of a self-adjusting nCPAP device based on impedance (APAP FOT) compared with constant nCPAP - a prospective randomized cross-over twelve weeks follow-up",
6th World Congress on Sleep Apnea, 12.-15.03.00, Sydney, 2000

Ficker J.H., Fuchs F.S., Wiest G.H., Asshoff G., Schmelzer A.H., Hahn E.G.
"An Auto-CPAP Device Controlled Exclusively By Forced Oscillation Technique",
Eur Respir J, 16, 914-920, 2000 [more information]

Randerath W., Parys K., Feldmeyer F., Sanner B., Rühler K.H.
"Self-Adjusting Continuous Positive Airway Pressure Therapy Based on the Measurement of Impedance, A comparison of Free Pressure Variation and Individually Fixed Higher Minimum Pressure",
Respiration, 67, 1, 2000 [more information]

Randerath W., Parys K., Feldmeyer F., Sanner B., Rühler K.H.
"Self-adjusting Nasal Continuous Positive Airway Pressure Therapy Based on Measurement of Impedance, A Comparison of Two Different Maximum Pressure Levels",
Chest, 116, 991, 1999 [more information]

Ficker J.H., Fuchs F.S., Wiest G.H., Asshoff G., Lehnert G., Hahn E.G.
"Das erste oszilloresistometrisch gesteuerte auto-CPAP- Gerät (SOMNOsmart) - eine Therapie des lageabhängigen Schlafapnoe-Syndroms?",
Somnologie, 3, 328, 1999

Randerath W., Büscher L., Galina G., Domanski U., Rühle K.-H.
"Automatische nCPAP Therapie auf der Basis der forcierten Oszillationstechnik (APAPFot)",
Somnologie, 3, 264, 1999

Ficker J.H., Wiest G.H., Lehnert G., Wiest B., Hahn E.G.
"Evaluation of an auto-CPAP device for treatment of obstructive sleep apnea"
Thorax, 53, 643, 1998